BXQ-防动力电磁启动配电箱 适用范围
1. 炸性气体环境危险场所:1区、2区; 2. 可燃性气体、蒸气级别:ⅡA、ⅡB; 3. 温度组别:T1~T4; 4. 户内、户外(IP54)。 1. For the dangerous sites with explosive air mixture: 1 division、2 division; 2. Flammable gas, steam class: ⅡA、ⅡB; 3. Temperatures classification:T1~T4; 4. Indoor and outdoor(IP54).
产品特点 1. 外壳采用铸铝合金或钢板焊接而成; 2. 内装ABB或施耐德等公司生产的固态软起动器,采用逐步升压 的方法,实现平滑起动; 3. 可根据负载特性选用常规起动和重载起动,起动参数可自行设 定。 4. GB3836-2000、IEC60079, GB12476.1-2000、IEC61241 标准要求。 1. The shell is made of diecasted Al-alloy of welded of steel plates; 2. Inside will be installed ABB or Schneiders solid soft starter, which increase voltage step by step to flatly start; 3. It shall select the starting mode from normal type and heavy loaded type according to load characteristics, starting parameter can be self-set. for GB3836-2000、IEC60079, GB12476.1-2000、IEC61241 standard request.
技术参数 型号 Model 电机功率(W) Motor power 额定电流 Rated current (A) 防标志 Explosion- proofing marker 防护等级 Protection category 进线口螺纹 Inlets and outlet thread 电缆外径 Cables outside diameter (mm) BQXR51-15 15 30 ExdⅡ BT4 IP54 G11/4 Φ15~22 BQXR51-22 22 37 BQXR51-30 30 50 G11/2 Φ20~26 BQXR51-45 45 72 BQXR51-55 55 70~110 G2 Φ27~34 BQXR51-75 75 87.5~145 BQXR51-90 90 105~175 G21/2 Φ36~44
|