| 是否提供加工 | 否 | | SEINTL | | 型号 | Inspector Xtreme | 测范围 | 1 | | 测对象 | 1 | 测精度 | 1 | | 分辩率 | 1 | 尺寸 | 178 x 95 x 41(mm) | | 重 | 0.275(kg) |
SEINTL辐射探测器Inspector 辐射表辐射检测仪 SEINTL手持式辐射探测器Inspector EXP+ 辐射表辐射检测仪 SEINTL手持式辐射探测器Inspector Xtreme 辐射表辐射检测仪 如需更详细资料或报价请资询: 龙定国 15989522114 Tel: 86-755-82444742 Fax: 86-755-82413857 Mail:terry@ 15989522114@ Q Q: 32174454 MSN:longdingguo2003@ Web: Inspector多功能射线仪可检测Χγαβ射线 Inspector是小的手持式微处理器控制的高灵敏度低水平能检测Χγαβ射线。直接读出射线水平。另外,有可调整的定时器和外部校准键。 检测器: 具有云母窗口的GM管,窗口有效直径45 mm Inspector (只有内部GM管) 在前面板中心有射线标记标记 Inspector EXP(只有外部探头) 在仪器外部具有把手,有与Inspector相同的GM管探头。 电源要求:一节9V碱性电池。电池寿命200小时 该剂仪采用一支盖革-弥勒计数管来测定αβγ及Χ射线辐射,数字显示,探头为内置式,使体积更小灵敏度更高。 技术指标: 剂率:mR/hr(毫伦/小时) 0.001~100μSV/ hr(微希伏/小时) 0.01~1000 计数:CPM(每分钟计数)0~300000 CPS(每秒钟计数)0~5000 计数时间选择:为了精确测低计的α线和β射线可选择1分-24小时 连续计数再除以计数时间变为CPM或CPS 精度:<±15% 重:272g 体积:150×80×30㎜ Inspector Handheld Digital Radiation Alert® Detector a ß y x The Inspector is a small, handheld, microprocessor-based instrument which offers excellent sensitivity to low levels of alpha, beta, gamma, and x-rays. The digital readout is displayed with a red count light and a beeper sounds with each count detected. Other features include an adjustable timer, external calibration controls and adjustable alert. Specifications Detector Internal Halogen-quenched, uncompensated GM tube with thin mica window, 1.4-2.0 mg/cm2 areal density. Effective diameter of window is 45 mm (1.75 in.). Radiation symbol on front label marks the center of the detector. Display 4 digit liquid crystal display with indicators. Averaging Periods Display will update every 3 seconds. At low background levels, the update is the moving average for the past 30-second time period. The timed period for the moving average decreases as the radiation level increases Energy Sensitivity Detects Alpha down to 2 Beta down to .16 MeV; typical detection efficiency at 1 MeV is approx. 25%. Detects Gamma down to 10 KeV through the end window. 3340 CPM/mR/hr (Cs137). Smallest detectable level for I125 is .02 µCi at contact. Operating Range mR/hr - .001 (1µR) to 100 CPM - 0 to 350,000 µSv/hr - .01 to 1000 CPS - 0 to 5000 Total/ Timer - 1 to 9,999,000 counts Accuracy mR/hr ±10% typical (NIST), ±15% max - 0 to 100 µSv/hr ±10% typical (NIST), ±15% max - 01 - 1000 CPM ±10% typical (NIST), ±15% max - 0 to 350,000 (Referenced to Cs-137) AlertSet Range mR/hr .001 - 50 and CPM 1 - 160,000. 70db @ 1m. Count Light Red LED flashes with each radiation event. Audio Indicator Internally mounted beeper (can be switched off for silent operation) Outputs Dual miniature jack drives CMOS or TTL devices: count to computer or datalogger. Submini jack input allows for electronic calibration Anti-Saturation Meter will hold at full scale in fields as high as 100 times the maximum reading. Power Requirements One 9-volt alkaline battery. Battery life is approx. 2160 hours at normal background. TemperatureRange -10ºC to 50ºC (14ºF to 122ºF) Weight Inspector: 273 grams (9.6 oz.) without battery. Size 150 x 80 x 30 mm (5.9 x 3.1 x 1.2 in.). Includes Carrying Case, CE Certification Options Observer Software, Xtreme Boot, Waterproof Case (Gamma & X-Ray Only), & Wipe Test Plate Limited Warranty 1 year limited, 90 day Warranty on GM Detector Utility Menu The Utility Menu offers several options accessible by holding down the + button while turning the instrument on. •3 second (fast response) •Switches from mR/hr and CPM to µSv/hr and CPS •Reset the cal factor to 100. •Adjust the CAL factor. •Reset all setting to default factory setting. Accessories Xtreme Boot Waterproof Case Observer Software Stand Wipe Test Plate
Inspector EXP+ Handheld Digital Radiation Alert® Detector a ß y x The Inspector EXP was designed to meet the requirements of emergency response personnel. It has the same valuable features, small size, and quality of the Inspector. However, instead of the built-in detector, it has the added versatility of an external probe. The carrying case has a clear window panel providing full view of the readout, count light, access to the switches, and a convenient belt loop for carrying the instrument. A small pocket is provided for a check source. The protective probe cover on the uniquely designed carrying case folds easily out of the way to allow one-handed operation if desired. Specifications Detector RAP-RS1 Probe - External Halogen-quenched, uncompensated GM tube with thin mica window, 1.4-2.0 mg/cm2 areal density. Effective diameter of window is 45 mm (1.75 in.). Radiation symbol on front label marks the center of the detector. Display 4 digit liquid crystal display with indicators. Averaging Periods Display will update every 3 seconds. At low background levels, the update is the moving average for the past 30-second time period. The timed period for the moving average decreases as the radiation level increases AlertSet Range mR/hr .001 - 50 and CPM 1 - 160,000. 70db @ 1m. Count Light Red LED flashes with each radiation event. Audio Indicator Internally mounted beeper (can be switched off for silent operation) Outputs Dual miniature jack drives CMOS or TTL devices: count to computer or datalogger. Submini jack input allows for electronic calibration Energy Sensitivity Detects Alpha down to 2 Beta down to .16 MeV; typical detection efficiency at 1 MeV is approx. 25%. Detects Gamma down to 10 KeV through the end window. Anti-Saturation Meter will hold at full scale in fields as high as 100 times the maximum reading. Power Requirements One 9-volt alkaline battery. Battery life is approx. 2160 hours at normal background. TemperatureRange -10º to 50ºC (14º to 122ºF) Weight Inspector: 273 g (9.6 oz.) Size 150 x 80 x 30 mm (5.9 x 3.1 x 1.2 in.) Probe: 260 X 70 X 38 mm (10.25 X 2.75 X 1.5 in) Probe Construction Anodized aluminum housing Size - Approx. 8.75 in. (22.23 cm) Dia.: 2.75 in. (7.0 cm) Connector - Amphenol-Tucal Handle - Black foam grip Weight - Approx. 11.5 oz. (328 g) w/o cable Gamma Sensitivity 3340 CPM/mR/hr referenced to Cs137. Smallest detectable level for I-125 is .02 µCi at contact. Timer can set 1 minute sampling periods from 1 to 10 minutes. Operating Range mR/hr - .001 (1µR) to 100 mR/hr CPM - 0 to 350,000 µSv/hr - .01 to 1000 CPS - 0 to 5000 Total/ Timer - 1 to 9,999,000 counts Accuracy mR/hr ±10% typical (NIST), ±15% max - 0 to 100 µSv/hr ±10% typical (NIST), ±15% max - 01 - 1000 CPM ±10% typical (NIST), ±15% max - 0 to 350,000 (Referenced to Cs137) Includes Carrying Case, Cable for Inspector+ EXP: Beldon 9853 with Amphenol 31226 twinax. CE Certification. Limited Warranty 1 year Limited Warranty, 90 day Limited Warranty on GM detector Utility Menu The Utility Menu offers several options accessible by holding down the + button while turning the instrument on. •3 second (fast response) •Switches from mR/hr and CPM to µSv/hr and CPS •Reset the cal factor to 100. •Adjust the CAL factor. •Reset all setting to default factory setting. Accessories Observer Software
Inspector Xtreme Handheld Digital Radiation Alert® Detector a ß y x The Inspector Xtreme offers maximum performance in a lightweight, rugged solution for using your survey meter in the field. The Inspector Xtreme is designed specifically for individuals operating in tough environments, such as 1st Responders, miners, and HAZMAT crews. The unit is a small, handheld, microprocessor-based instrument which offers excellent sensitivity to low levels of alpha, beta, gamma, and x-rays. The digital readout is displayed with a red count light and a beeper sounds with each count detected. Other features include an adjustable timer, external calibration controls,and selectable alert. Specifications Detector Internal Halogen-quenched, uncompensated GM tube with thin mica window, 1.4-2.0 mg/cm2 areal density. Effective diameter of window is 45 mm (1.77 in.). Radiation symbol on front label marks the center of the detector. Display 4 digit liquid crystal display with indicators. Averaging Periods Display will update every 3 seconds. At low background levels, the update is the moving average for the past 30-second time period. The timed period for the moving average decreases as the radiation level increases. Energy Sensitivity Detects Alpha down to 2 MeV. Detects Beta down to .16 MeV; typical detection efficiency at 1 MeV is approx. 25%. Detects Gamma down to 10 KeV through the end window. 3340 CPM/mR/hr (Cs137). Smallest detectable level for I125 is .02 µCi at contact. Operating Range mR/hr - .001 (1µR) to 100 CPM - 0 to 350,000 µSv/hr - .01 to 1000 CPS - 0 to 5000 Total/ Timer - 1 to 9,999,000 counts Accuracy mR/hr ±10% typical (NIST), ±15% max - 0 to 100 µSv/hr ±10% typical (NIST), ±15% max - 01 - 1000 CPM ±15% max - 0 to 350,000 (Referenced to Cs-137) AlertSet Range mR/hr .001 - 50 and CPM 1 - 160,000. 70db @ 1m. Count Light Red LED flashes with each radiation event. Audio Indicator Internally mounted beeper (can be switched off for silent operation) Outputs Dual miniature jack drives CMOS or TTL devices: count to computer or datalogger. Submini jack input allows for electronic calibration Anti-Saturation Meter will hold at full scale in fields as high as 100 times the maximum reading. Power Requirements One 9-volt alkaline battery. Battery life is approx. 2160 hours at normal background. TemperatureRange -10º to 50ºC (14º to 122ºF) Weight Inspector: 275 grams (9.7 oz.) without battery. Size 178 x 95 x 41 mm (7 x 3.8 x 1.6 in.) Utility Menu The Utility Menu offers several options accessible by holding down the + button while turning the instrument on. 3 second (fast response) Includes Xteme Boot, CE Certification Limited Warranty 1 year Limited Warranty, 90 day Limited Warranty on GM Tube Utility Menu The Utility Menu offers several options accessible by holding down the + button while turning the instrument on. •3 second (fast response) •Switches from mR/hr and CPM to µSv/hr and CPS •Reset the cal factor to 100. •Adjust the CAL factor. •Reset all setting to default factory setting. Access to End Panels on Inspector, Digilert, and Geiger Models with Xtreme Boot Accessories Xtreme Boot Waterproof Case Observer Software Stand Dashboard Mount Wipe Test Plate
|