山东济南水泥浆电磁流计
XBOLDBE青岛鑫博智能电磁流计 鑫博电磁流计是为供水企水计贸易门设计的,具有防水、防腐、防、防击的能力。 电磁流计在满足现场显示的同时,还可以输出4~20mA电流供记录、调节和控制用,现已地应用于化工、环保、冶金、造纸、给排水等工技术和管理部门。可以用于测、碱、盐溶液、水煤浆、矿浆、砂浆灰泥、纸浆、树脂、橡胶乳、合成纤维浆和感光乳胶等各种悬浮物、气化汽和粘性物的流。电磁流计密封性能好,还可用于自来水和地下水道系统。而且测过程不与流体接触,适于制、生物化学和食品工。
水泥浆智能电磁流计流对照表 流速——流对照表 | 流速m/s 流m3/h 通径mm | 0.01 ( 小) | 1 | 2 | 3 | 4 | 5 | 15 (大) | 15 20 25 40 50 65 80 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1200 1400 1600 1800 2000 2200 2400 2600 | 0.0064 0.0113 0.0177 0.452 0.0707 0.1195 0.1810 0.2827 0.6362 1.1310 1.7671 2.5447 3.4636 4.5239 5.7256 7.0686 10.1788 13.8544 18.0956 22.9022 28.2743 40.71.50 55.4177 72.3823 91.6088 113.0973 136.8478 162.8602 191.1343 | 0.6362 1.1310 1.7671 4.5239 7.0686 11.9459 18.0956 28.2743 63.6173 113.0973 176.7146 254.4690 346.3606 452.3893 572.5553 706.8583 1017.8760 1017.8760 1385.4424 1809.5574 2290.2210 2827.4334 4071.5041 5541.7694 7238.2295 9160.8842 11309.7336 136286.0163 19113.4268 | 1.2723 2.2619 3.5343 9.0478 14.1372 23.8918 36.1911 56.5487 127.2345 226.1947 353.4292 508.9380 692.7212 904.7787 1145.1105 1413.7167 2035.7520 2770.8847 3619.1147 4580.4421 5654.8668 8143.0082 11083.5389 14476.4589 18321.7684 22619.4671 27369.5552 32572.0326 38226.8536 | 1.9085 3.3929 5.3014 13.5717 21.2058 35.8377 54.2867 84.8230 190.8518 339.2920 530.1438 763.4070 1039.0818 1357.1680 1717.6658 2120.5750 3053.6281 4156.3271 5428.6721 6870.6631 8482.3002 12214.5122 16625.3083 21714.6884 27482.6525 33929.2007 41054.3328 48858.0490 57340.2804 | 2.5447 4.5239 7.0686 18.0956 28.2743 47.7836 72.3823 113.0973 254.4690 452.3893 706.8583 1017.8760 1385.4424 1809.5574 2290.2210 2827.4334 4071.5041 5541.7694 7238.2295 9160.8842 11309.7336 16286.0163 22167.0778 28952.9179 36643.5367 45238.9342 54739.1104 65144.0653 76453.7072 | 3.1809 5.6549 8.8357 22.6195 35.3429 59.7295 90.4779 141.3717 318.0863 565.4867 883.5729 1272.3450 1731.8030 2261.9467 2962.7763 3534.2917 5089.3801 6927.2118 9047.7868 11451.1052 14137.1669 20357.5204 27708.8472 36191.1474 45804.4209 56548.6678 68423.8880 81430.0816 95567.1340 | 9.5426 16.9646 26.5072 67.8584 106.0288 179.1886 271.4336 424.1150 954.2588 1696.4600 2650.7188 3817.0351 5195.4089 6785.8401 8588.3289 10602.8752 15268.1403 20781.6354 27143.3605 34353.3157 42411.5008 61072.5612 83126.5416 108573.4421 137413.2627 169646.0033 205217.6640 244290.2448 286701.4020 |
电磁流计故障分析: 1、非轴对称流动引起的误差,首先为了避免误差,必须保流体流速为轴对称,而且在选装电磁流计时要尽可能保直管段的要求以减小其所引起的误差。 2、流体电导率的问题,如果流体电导率的降低,电极的输出阻抗会有所增加,所以在一般测的流体电导率的下限为5μS/㎝~10μS/㎝,若电极直径为1㎝,则电极的输出阻抗为1/Kd=100kΩ~200kΩ,为使输出阻抗的影响限制在0.1%以下,转换器的输入阻抗应为200MΩ左右。 3、电极衬里附着物的影响,如果在测时有沉淀物的流体附着时,电极的表面会受到污染,零点会出现变动,所以一定要注意这点。 4、传输电缆长度的问题,当电缆长度超过大长度时,由电缆分布电容引起的负载应成了问题,为了避免这种情况的发生,一定要由转换器提供低阻抗电压源使内侧屏蔽与芯线得到相同的电压,以形成屏蔽。 5、励磁的技术问题,励磁频率降低,零点稳定性可以,但仪表抗低频能力减弱,响应速度慢,如果励磁频率高,则抗低频的能力增强,但仪表的零点稳定性降低。 6、传感器接地的问题,良好的接地决定着流计的测准确度,如果当外来存在时,对它的影响会的大。
|